Refrigerator

Refrigerator
6
amps
6
watts
700
voltage
120
gauge
14 AWG
max Length
6
notes
Refrigerators should not use extension cords long-term. If temporary, use 14 AWG max 6 ft. Compressor startup surge can be 3x running amps.

What size extension cord for a Refrigerator?

A refrigerator draws about 6 amps (700W) at 120V. To carry that safely you need at least 14 AWG copper, and even then only for short runs, up to roughly 6 ft before voltage drop and heat become a problem. Thinner cord (the common 16 AWG household type) can overheat under this load and is a fire risk.

Current draw
6 A
Power
700 W
Min gauge
14 AWG
Max length
6 ft

Cord gauge by length for a refrigerator

The longer the cord, the thicker it must be to keep voltage drop under 3% at 6A. Minimum recommended copper gauge by run length:

Cord lengthMinimum gaugeNotes
25 ft14 AWGMinimum safe gauge
50 ft14 AWGMinimum safe gauge
100 ft14 AWGMinimum safe gauge
150 ft12 AWGUpsized for the longer run

Safety note

Refrigerators should not use extension cords long-term. If temporary, use 14 AWG max 6 ft. Compressor startup surge can be 3x running amps.

Why gauge matters

A smaller AWG number means thicker copper and lower resistance. Undersized cord drops voltage (making motors and heating elements work harder) and turns the lost energy into heat in the cord itself. At 6A, a too-thin or coiled cord can get hot enough to melt insulation. Always uncoil cords fully during use, and never chain two cords together for a high-draw refrigerator.

Frequently asked questions

What gauge extension cord for a refrigerator?

Use at least 14 AWG copper for a refrigerator (6A). For runs longer than 6 ft, step up to the next thicker gauge to hold voltage drop under 3%.

How long can the extension cord be?

At 14 AWG, keep it to about 6 ft for a refrigerator. Beyond that, use a thicker cord: see the gauge-by-length table above.

Can I use a regular 16 AWG cord?

No. A standard 16 AWG household cord is not rated for the 6A a refrigerator draws and can overheat. Use 14 AWG or thicker, and ideally plug the refrigerator directly into a wall outlet.

Data sources: NEC 2023 ampacity and voltage-drop guidance; UL extension-cord ratings; manufacturer nameplate data. Gauge-by-length figures use a 3% voltage-drop target at the stated current. Always follow the appliance manufacturer instructions.

Disclaimer: For reference only. Consult a licensed professional.